How to choose a glass partition supplier: 7 checks you can actually verify
Most supplier lists are not the problem. Verification is. A shortlist of names tells you nothing about whether the company extrudes its own profile, whether the glass is certified, or whether the crew that turns up is theirs. These seven checks can all be done before you sign, most of them remotely, and each one has an answer that is either verifiable or not.
1. Is it a factory or a broker?
The distinction decides who answers when something goes wrong with a profile, a door or a delivery date. A factory can change a die or re-machine a part; a broker has to ask someone else.
You do not need to visit to establish this. Ask for a live video call walking through the workshop, with the extrusion press or the machining line visible and a component you can identify in the frame. Stock footage and showroom walk-throughs do not answer it.
- Registered company name and business scope on the public corporate register.
- Whether the address is a workshop or a serviced office.
- Whether they can show the same profile being cut or machined today.
2. Profile wall thickness and alloy
The main structural profile is where cost is saved quietly. A 1.2 mm wall and a 2.0 mm wall look identical once powder-coated and installed; they behave differently under a 3 m clear span, a heavy glass leaf and a door that is used fifty times a day.
Ask for the nominal wall thickness per series in writing, and for the alloy designation. Then compare the same series across suppliers.
- Wall thickness of the main profile, in millimetres, per series.
- Alloy and temper of the extrusion.
- Whether the profile is standard stock or a dedicated die for this system.
3. Glass certification
Tempered glass for a commercial interior should carry certification, and the marking should be visible on the pane edge or in the documents. Annealed glass in a partition next to a doorway is a safety problem, not a saving.
Ask what is specified and what is delivered: 12 mm single, laminated, or a sealed double-glazed unit, and which standard the tempering is certified against.
- Tempered or laminated, and the nominal thickness per panel.
- Where the certificate comes from and whether it covers the delivered batch.
- How panels are edge-worked and whether any cut-outs are done before tempering.
4. Third-party test report numbers
A test report number is one of the few claims you can check independently. Acoustic performance, wind load, water tightness and fire classification all come with a report, and the report has a number, a laboratory and a date.
A supplier who has them will send the numbers without hesitation. A supplier who answers with adjectives has not been tested.
- Report number, laboratory and test date for each claimed performance figure.
- Whether the tested assembly matches what you are buying.
- Whether the report is still within its validity period.
5. Own installation crew or subcontracted
The wall in the drawing becomes the wall on site through the installers. If the crew is subcontracted per project, the quality of your wall depends on which crew happens to be free that week.
Ask directly, and ask how long the installers have worked with the company. Long tenure is the cheapest quality signal there is.
- In-house crew or subcontracted, and for how many years.
- How many crews, and which one is assigned to your project.
- Who is accountable on site and who you call when something is wrong.
6. Itemised quotation
An itemised quotation is evidence that the supplier has actually measured and detailed your project. A single rate per square metre is not wrong, but it cannot show you the doors, hardware, blinds, base detail or handover documents.
The same principle applies to what is excluded: a good supplier writes the exclusions down, because they would rather tell you now than argue later.
- Wall area by system, then separate lines for doors, hardware, blinds, installation and making-good.
- Explicit exclusions list.
- Lead time per phase, including glass and blind production.
7. Real site evidence with dates
Photographs of finished offices are easy to obtain. Photographs that identify a project, a date and a system are harder.
Ask for two projects in your city that you can visit, and for the delivery date on each. If the addresses are real, a site visit answers more in ten minutes than a week of catalogue reading: base detail, sealant lines, door alignment and how the walls have aged.
- Two visitable projects near you, with dates.
- Photos of the same detail — base, head, junction, door — across projects.
- Permission to speak to the person who signed off the last job.
A note on what a supplier should not promise
Be cautious with any supplier who gives a single decibel figure as a guarantee, or who promises that a glass wall will be as quiet as a solid one. Acoustic performance depends on the glazing build-up, the sealing, the door and the return-air path together, and it is measured as a system.
The honest answer is a method: which seals, which door bottom, which cavity, and what has been measured on a comparable assembly.
Frequently asked questions
Do I need to visit a factory before choosing a glass partition supplier?
Not necessarily. A live video call showing the machine line and a specific component, plus reports and two visitable projects with dates, establishes most of what a visit would.
What profile wall thickness should an office partition have?
It depends on the system and the span, but the nominal wall thickness of the main structural profile should be stated in writing per series — commonly between 1.2 mm and 2.0 mm for commercial systems. Ask for the figure that applies to your drawing.
Which glass certificate should I ask for?
The certificate covering the tempering of the delivered batch, with the standard it is certified against, plus the nominal thickness per panel. The marking on the pane should be consistent with the documents.
How do I check a test report is relevant?