# All-steel fire-rated partition systems

Two all-steel systems for fire compartment lines and escape routes. M-116 is Class A, insulating: it holds back heat as well as flame. MJ-95 is Class C, non-insulating, on the same frame construction. Both use roll-formed steel profiles with graphite intumescent strips and take fire-rated glass from 6 mm to 38 mm.

- [Request a quotation](https://en.mijiaeg.com/contact.html)
- [View all product systems](https://en.mijiaeg.com/products/)

![Cut sections of the roll-formed all-steel fire-rated profile](https://en.mijiaeg.com/assets/img/fire-rated-profile-section.jpg)

*Cut sections of the all-steel fire-rated profile: roll-formed steel, with the graphite intumescent strip in the glazing rebate.*

## Class A or Class C - the difference

The difference is what the partition has to do in a fire, not how it is built: both systems use the same all-steel frame, intumescent strip and glazing range.

*Class A - insulating*

### M-116 - integrity and insulation

A Class A partition resists the passage of flame and limits the heat crossing it. Specify it where the compartment line must hold back heat as well as fire, for example between a compartment and the escape route serving it.

*Class C - non-insulating*

### MJ-95 - integrity only

A Class C partition resists the passage of flame and hot gases but is not required to limit heat transfer. It suits areas where containing fire and smoke is the requirement.

## M-116 and MJ-95 compared

Ratings are selected per project. Give us the class and the rating the fire strategy calls for and we build the frame and glazing around it.

|  | M-116 | MJ-95 |
| --- | --- | --- |
| Fire class | Class A - insulating (integrity + insulation) | Class C - non-insulating (integrity) |
| Overall thickness | >= 105 mm, visible face 45 mm | >= 105 mm, visible face 45 mm |
| Frame profiles | All-steel, roll-formed from steel-mill coil, wall 1.2-1.5 mm | All-steel, roll-formed from steel-mill coil, wall 1.2-1.5 mm |
| Intumescent strip | Graphite, expansion ratio >= 30x | Graphite, expansion ratio >= 30x |
| Glazing | 6-38 mm monolithic, laminated or composite fire-rated glass; double or offset single glazing, one or both sides | 9 + 9 mm double fire-rated glazing as standard; also 6-38 mm monolithic, laminated or composite |
| Fire resistance rating | >= 1.0 h, > 1.5 h or >= 2.0 h (integrity + insulation), selected per project | Integrity only > 180 min (C3.0 h); insulating ratings from >= 1.0 h to >= 2.0 h where specified |
| Typical use | Fire compartments, high-rise floors, public venues, escape routes | Plant-room and factory divisions, public spaces, fire upgrades |

## How the system is built

- **Roll-formed steel profiles** - Frame sections are roll-formed from steel-mill coil to a wall thickness of 1.2-1.5 mm. They resist deformation, so a long run holds its line.
- **Graphite intumescent strip** - A graphite strip inside the frame expands by at least 30 times its volume when heated and keeps clamping the glass in place.
- **Fire-rated glass, 6-38 mm** - Monolithic, laminated and composite fire-rated glass fit the same glazing detail. M-116 takes glass on one or both sides; MJ-95 is supplied double-glazed 9 + 9 mm.
- **Modular build** - Frames assemble from modular sections, which keeps installation on site quick and lets a bay be opened again for later maintenance.

## Where these systems are used

- **Fire compartment lines** - Partitions that divide a floor plate into compartments, with the frame line following the compartment drawing.
- **Escape routes and corridors** - Glazed screens along corridors that stay bright while separating the route from the space beside it.
- **High-rise office floors** - Compartment and lobby screens running from floor slab to soffit.
- **Public buildings and plant rooms** - Foyers, halls and circulation areas with a defined fire strategy; divisions around plant and production areas.

## Documentation

Mingjia builds these systems to a stated construction and a stated rating, and makes no third-party fire approval claim for the assemblies themselves. The class and rating you specify - Class A at >= 2.0 h, for example - are confirmed against your project's fire strategy before they are relied on, and the frame, glazing and intumescent build-up is set out in writing.

The third-party reports we can publish cover other systems, and we keep them separate on purpose: the steel-core aluminium-clad partition system, measured at Rw 46 dB with wind load resistance Class 5, water tightness Class 4 and reaction to fire Class B1 to GB 8624-2012 (report no. CS425113133AQ734Z); and our aluminium profiles, tested to the GB/T 5237 series with all 19 items conforming (report no. CS925706226AQ947Z). Neither covers the fire-rated assemblies. Details are on the [certificates page](https://en.mijiaeg.com/certificates.html).